Preparing The Ground - Minebea Intec Novego Manuel D'installation

Masquer les pouces Voir aussi pour Novego:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Hygienic Weighing Module Novego®
5.1.2

Preparing the ground

Minebea Intec
NOTICE
No leak-tightness of the supporting/sealing surface present between pendulum
base and substructure.
Leak-tightness between the pendulum base (2) and substructure (4) must be
ensured using O-ring (3).
.
The load distribution on the available load cells must be as even as possible to
prevent overload of the individual load cells.
.
Use the drilling template to generate the drilling pattern of the pendulum bases (see
Chapter 4.4) according to the weighing system arrangement.
.
The contact surfaces of the pendulum bases (2) and the contact surfaces of the vessel
feet (1) must be arranged in parallel.
.
It is imperative to observe the maximum permissible inclination (≤1 mm); refer to
igure.
The ground must be designed as follows for the pendulum base:
-
horizontal (spirit level!) supporting/sealing surface
Note:
A pendulum base with tilt correction compensates for any inclination of ≤3°.
-
lat supporting/sealing surface
-
suicient load carrying capacity for the provided loads
.
The load distribution on the available load cells must be as even as possible to
prevent overload of the individual load cells.
.
It is imperative to observe the maximum permissible inclination; refer to igure!
5 Installation
EN-18