warning
Risk of injury due to non-conforming maintenance.
•
Maintenance must only be carried out by qualified and skilled
staff with the appropriate tools.
•
Make sure that the restart of the installation is controlled after
any interventions.
9.2.
maintenance of the strainer
→
After the circulation of 200 liters of fluid, examine the strainer
for particles. If necessary clean the strainer with a product com-
patible with the materials from which it is made.
→
Regularly examine the strainer for good condition, in particular
when the flow rate decreases. If necessary clean the strainer
with a product compatible with the materials from which it is
made.
9.3.
maintenance of the sensor
→
Regularly examine the seal and the oval rotors for good
condition. Follow the instructions on chap. 9.4. and 9.5.
The 8071 sensor can be cleaned with a cloth dampened with water
or a product compatible with the materials from which it is made.
Your Bürkert supplier is at your disposal for any further information.
16
english
Type 8071
Maintenanceandtroubleshooting
9.4.
dismantle the sensor
1
2
3
4
5
Fig.8
Exploded view of the 8071 sensor
→
Unscrew the 4 screws (mark 5
(mark 4 Fig.8).
→
Remove the seal (mark 3
Fig.8).
→
Examine the seal for good condition. If not, replace it by a new
one (see chap. 10. Spare parts and accessories).
→
Remove the rotors (mark 2
→
Examine the rotors for good condition. If necessary, clean or
replace them (see chap. § 10. Spare parts and accessories).
grooves
Fig.8) and remove the cover
Fig.8).