5.2.2.
measuring principle
When the fluid flows through the pipe, the oval rotors which contain
magnets turn (see Fig.1). The displacement of magnets lead to a
variation of magnetic field. The sensor measures the variation of
the magnetic field and converts the signal into a frequency. The
frequency is available at both the NPN transistor and Reed switch
outputs.
Fig.1
Running/displacement of oval rotors
The remote device converts the frequency into a flow rate by using
the correct K factor.
5.3.
description de l'étiquette
Type 8071 Flow Sensor
1
Model
2
Flow Range
3
Max Pressure
1000kPa/55Bar
4
Max Temp
5
Serial No
Fig. 1:
Label of the 8071 sensor
6
433864N
2-100LPH
120°C
D34128
english
Type 8071
Description
1.
Ordering code
2.
Flow rate range
3.
Maximum pressure of the fluid
4.
Maximum temperature of the fluid
5.
Series number