2.3
GENERAL INFORMATION
2.3.1 FEATURES
•
Maximum log length of 24"
•
Long burn time - up to 12 hours
•
Thermostat for automatic control of the blower
•
Large fi rebox capacity
2.3.2 HEATING SPECIFICATIONS
DO NOT LET THE APPLIANCE BECOME HOT ENOUGH FOR ANY PART TO GLOW RED.
IMPORTANT
Differences in chimney height and draft may lower overall burn times.
Approximate Heating Capacity up to 2,000 square feet (Will vary with the home's fl oor plan, insulation and
outside temperature).
Maximum burn time up to 12 hours.
BTU Output per hour 10,000 to 80,000.
Oil furnace module up to 91,000 BTU input.
Electric furnace up to 20 Kw.
2.3.3 ELECTRICAL SPECIFICATIONS
Fully confi gured furnace 11 amps, 120 V, for optional electric furnace module 84 amps, 220 V.
2.3.4 OPTIONAL MODULES
Optional Modules Available:
• Blower Box Module HMFK-BMP33
• Electric Furnace Module HMFK-EF20
• Oil Furnace Module HMFK-OFRF40, HMFK-OFAFG
• "Add On" Furnace Module HMFK-ADDON
2.3.5 APPLICABLE STANDARDS
Certifi cation Standards and Installation Codes:
L391
UL727
CSA B366.1-M91
B140.4-04
CSA B212-00
CSA B365-01 (R2006)
2.3.6 CALIFORNIA PROP65
Use of this product may produce smoke which contains chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
•
Choice of glass door for radiant heat through front
of furnace, or solid door to provide more heating
through exchange surfaces
•
Firebrick lining for fi rebox creates kiln like
temperatures for maximum effi ciency and low
emissions
•
Outside air for combustion
CSA B139-09
NFPA 211
CSA 22.1
CAN/CSA-C22.2 NO.0-M91
CAN/CSA-C22.2 NO.3-M1986
ANSI/NF NO.70
7
W415-0910 / A / 09.16.10