GENERAL PLENUM AND DUCTING - CLEARANCE TO COMBUSTIBLES

All plenum and ducting clearances must satisfy specifi cation set forth in CAN/CSA-B365.01 and NFPA211.
CLEARANCE TO
COMBUSTIBLES
TOP
BOTTOM/SIDES
6.4

FLUE CONFIGURATION FOR "ADD ON" FURNACE CONFIGURATION

Separate chimneys are required when connecting the HMF150 to a pre existing natural gas or propane
furnace.
UNDER NO CONDITIONS MAY A SOLID FUEL BURNING APPLIANCE SHARE A CHIMNEY THAT
DO NOT USE MAKESHIFT COMPROMISES DURING INSTALLATION. DO NOT BLOCK OR RESTRICT
AIR. DO NOT IMPEDE AIR MOVEMENT ZONES MARKED "CLEARANCE TO COMBUSTIBLES".
ALL PLENUM DUCTING AND VENTING INSTALLATION MUST CONFORM WITH CAN/CSA B365-
01, CSA B139-09, AND NFPA 211. ALWAYS CHECK LOCAL BUILDING AND FIRE CODES , AND
NOTE:
See
CAN/CSA-
B365.01 and
NFPA211 for
clearance to
combustible
specifications
for return air
ducting.
A
6"
18"
VENTS NATURAL GAS OR PROPANE EXHAUST.
AUTHORITIES HAVING JURISDICTION.
CLEARANCE TO COMBUSTIBLES
6"
A
40"
72"
SECTION
B
6"
6"
1"
B
C
>72"
*Drawing not to scale.
C
1"
1"
W415-0910 / A / 09.16.10
41