6.0 PLENUM AND VENTING INSTALLATION/
CLEARANCE TO COMBUSTIBLE MATERIALS
ALL PLENUM DUCTING AND VENTING INSTALLATION MUST CONFORM WITH CAN/CSA B365-
01, CSA B139-09, AND NFPA 211. ALWAYS CHECK LOCAL BUILDING AND FIRE CODES , AND
ALL PLENUM, DUCTING AND VENTING MUST BE INSTALLED BY A QUALIFIED/LICENSED
DO NOT USE MAKESHIFT COMPROMISES DURING INSTALLATION. DO NOT BLOCK OR RESTRICT
AIR. DO NOT IMPEDE AIR MOVEMENT IN ZONES MARKED "CLEARANCE TO COMBUSTIBLES".
MINIMUM CLEARANCE TO COMBUSTIBLE DIMENSIONS MUST BE IMPLEMENTED.
6.1

FLUE / CHIMNEY FOR HMF150 IN CONFIGURATIONS

stand alone wood furnace
combination wood/oil furnace
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE!!
THE WOOD FURNACE SECTION CAN OPERATE USING A MINIMUM 6" Ø FLUE PIPE, BUT WE
RECOMMEND THAT THE FLUE SIZE BE SET AT A MINIMUM OF 7" Ø WHERE THE FURNACE IS
TO BE SET UP AS (OR IN CONSIDERATION TO A FUTURE RETRO FIT TO A WOOD/OIL OR WOOD/
OIL/ELECTRIC COMBINATION. CHIMNEY MUST BE APPROVED FOR USE WITH WOODBURNING
6.1.1
Controlling Draft
• Use of inclined manual dampers are forbidden.
• Barometric dampers can be installed to maintain normal operating draft between 0.04" and 0.06" W.C
6.2

VENTING CONFIGURATION FOR WOOD/OIL COMBINATION FURNACE

VENTING CONFIGURATION FOR BRINGING SEPARATE WOOD AND OIL FURNACE FLUES INTO A COMMON VENT
1
2
3
4
5
LEFT HAND RA CONFIGURATION
AUTHORITIES HAVING JURISDICTION.
APPLIANCES (2100°F).
Legend
(ITEMS 1 THROUGH 11 BY INSTALLER)
6
1.
Vent/chimney in accordance with CAN/
CSA-B365-01, CSA B139-09, NFPA211,
7
construction and installation by qualifi ed
licensed installer
8
2.
7" T
3.
6" to 7" Increaser
9
4.
6" T
10
5.
6" End cap for clean out
6.
5" to 7" Increaser
7.
90° 5" Elbow
8.
Barometric damper
9.
45° 5" Elbow (change angle to suit incline)
10. WARNING: Oil fl ue to be mounted on same
side of furnace as blower box, to respect
11
clearance to combustible dimensions.
12
11. 90° 5" Elbow (offset in two directions)
12. Heat shield
INSTALLER.
combination wood/electric furnace
combination wood/electric/oil furnace
6
7
8
9
10
RIGHT HAND RA CONFIGURATION
W415-0910 / A / 09.16.10