7.4
ELECTRIC SCHEMATICS - WOOD/ELECTRIC FURNACE CONFIGURATION
WOOD LIMIT
JUMPER
9
4
2
IMPORTANT - FIELD INSTALLATION NOTES
A - MOVE WIRE #5 FROM TERMINAL #5 TO TERMINAL #6.
E - INTERLOCK RELAY
F - INTERLOCK CONTACTS (C1, C2)
SUMMER SWITCH
1
2
3
11B
10B
N
5
4
5
1
2
3
9
10
11
12
13
2
3
20
12
N
21
CIRCULATION FAN
SCHEMATIC VOLTAGE SEPARATOR
FIELD WIRE
120 VAC
L1
N
COM
16
A
14A
6
7
8
15
14
15
16
9A
1
2
3
ELECTRIC FURNACE
CONTROL
NAPOLEON PRODUCTS
HMF150 CONTROLS / CIRCUITRY DIAGRAM
"WOOD/ELECTRIC" FIELD WIRING
JUNE 3, 2010
G
R
24 VAC
WHITE
BLACK
RED
BLACK / YELLOW
F
C1
C2
4
5 6
7
8
9 10 11 12
47
E