Napoleon HYBRID 150 Instructions D'installation Et D'opération page 36

Masquer les pouces Voir aussi pour HYBRID 150:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

36
STEP #10
Lift open side of electric furnace module so as to allow mounting fl ange on bottom edge of electric furnace
box to clear top edge of retaining bracket fastened to the lower edge of the rectangular window, the
furnace side.
Lower the electric furnace/blower box assembly so the lower mounting fl ange of the electric furnace is
contained between the fl ange of the retaining bracket and the furnace side.
Align and fasten side and top mounting fl anges of the electric furnace module to the furnace side using 9 x
¼" hex head wildrill screws.
STEP #11
ALL ELECTRICAL WIRING AND CONNECTIONS MUST BE DONE BY A QUALIFIED ELECTRICIAN.
THE ELECTRICAL INSTALLATION MUST SATISFY ALL RELEVANT ASPECTS OF CSA 22.1 AND IN
ALL 115V PRE ASSEMBLED ELECTRICAL HARNESSES MUST BE INSTALLED AS PER
INSTRUCTIONS. NO 115/220V ELECTRIC CIRCUIT (HARNESS OR FIELD WIRING) MAY PASS
THROUGH CLEARANCE SPACE BETWEEN HMF150 FURNACE BOTTOM AND FLOOR.
DISCONNECT POWER FROM BOTH ELECTRIC FURNACE AND "ADD ON" FURNACE BEFORE
FAILURE TO COMPLY MAY RESULT IN ELECTRICAL SHOCK, FIRE, PROPERTY DAMAGE OR
ALL WIRING BRINGING 120V OR GREATER TO THE HMF150 AND ITS MODULES, SHALL BE AS
SPECIFIED IN ELECTRICAL CODE BUT MUST HAVE WIRE INSULATION VALUE OF NO LESS THAN 90°C.
MUST MAINTAIN A MINIMUM CLEARANCE OF 12" BETWEEN ELECTRIC WIRING CARRYING 120V OR
GREATER AND ALL SURFACES OF THE SUPPLY PLENUM AND DUCT WORK.
MAINTAIN MINIMUM 18" CLEARANCE BETWEEN ALL FURNACE EXHAUST COMPONENTS AND
Remove access panel from the side of blower box module.
Route harness "B" from lower electrical box of main electric electrical harness to access hole on the rear of
blower box.
Match and connect harness connectors "B" inside the lower electrical box and snap fl ex conduit connector
into side of electrical box.
Wires from other end of harness should pass through hole in rear of blower module, the 90° fl ex connector
should also be passed through and secured by connector nut on the inside of box.
BLOWER SIDE PANEL
W415-0910 / A / 09.16.10
PARTICULAR CAN/CSA-C22.2 NO. 0-M91, NO. 3-M1986.
SERVICING.
PERSONAL INJURY.
ELECTRICAL WIRING CARRYING 120V OR GREATER.
BLOWER HARNESS:
LOWER ELECTRICAL
BOX TO BLOWER
MODULE

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Hmf150