Clearance To Combustibles; Minimum Enclosure Clearances - Napoleon HIGH COUNTRY NZ3000 Instructions D'installation Et D'opération

Masquer les pouces Voir aussi pour HIGH COUNTRY NZ3000:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

20
5.1

CLEARANCE TO COMBUSTIBLES

MAINTAIN THESE MINIMUM CLEARANCES TO COMBUSTIBLES:
EN
Framed Enclosure:
Rear
Sides
Ceiling (Enclosure)
Ceiling (Room)
Chimney
Hot Air Gravity Ductwork Insulation
Objects placed in front of the appliance must be kept a minimum of 48" (1219.2mm) away from the front of the
appliance.
5.2

MINIMUM ENCLOSURE CLEARANCES

6" (152.4MM)
MIN
A minimum of 6" is required to combustibles from the
side of the appliance.
6"
(152.4MM)
MIN
NOTE: When constructing the enclosure allow
for fi nishing material thickness to maintain
clearances.
W415-0711 / D / 05.09.13
- 0" to stand-offs
- 6" (152.4mm)
- 84" (2133.6mm) from the base of the appliance
- 84" (2133.6mm) from the base of the appliance
- 2" (50.8mm)
- 1" (25.4mm)
29
(749.3MM)
6" (152.4MM)
42" (1066.8MM)
MIN
29
(749.3MM)
42" (1066.8MM)
6"
54" (1371.6MM)
(152.4MM)
MIN
"
1
/
2
75
5
/
"
16
(1913MM)
"
1
/
2