MANUAL INSTALLATION AND OPERATION WFP-75 8411 ENGLISH
OF 40)
8.3.3
Framing with forced air distribution kit
If a finishing material is installed inside the enclosure, its thickness must be added to the following
measurements.
The framing can be constructed of combustible materials.
O : Distance between framing and side fireplace standoff 18" (457 mm)
P : Framing width (Installation with centered fireplace) 73 ¾" (1873 mm)
L : Forced air duct
8.3.4
Framing with corner installation
Framing configuration should be used as a reference only. The framing can be constructed
of combustible materials.
If a finishing material is installed inside the enclosure, its thickness must be added to the following
measurements.
The M and N values are minimum measurements and may need to be increased to allow the
installation of the fresh air intake, the forced air distribution or the type of finishing material
used.
M : Framing depth 53 ½" (1359 mm)
N : Framing width (Installation with centered fireplace) 75 ½" (1918 mm)
11
Framing dimensions are for reference only. These measurements are recommended to prevent the ducts from being inside the standoff or have
too tight duct curves. Smaller dimensions can be used depending on the size and type of duct as well as the configuration of the installation.
HVAC duct, as per ULC S110 or UL 181, class 0 or class 1, must withstand temperatures up to 250oF.
12
WFP-75 8411
Stove Builder International Inc. | 46345 | Rev: Apr 13 2020 12:33PM | Uncontrolled Copy
.
12
11
(21
Page 21
Page 710 of 971