OPERATION
Settings
4.
Settings
4.1
Selecting the set temperature
1
2
Memory 1
Memory 2
Maximum
Weather
Radio
ECO
3
1 Buttons "-" and "+"; press and hold to go faster
2 Rapid selection of preferred temperature with the memory
buttons
3 Touch-Wheel
4 Mini wireless remote control buttons
- Set temperature selection: 20 - 60 °C (factory setting) in
0.5 °C increments. From 43 °C (risk of scalding) the tempera-
ture display on the Touch-Display turns red
- "OFF" = heating system switched off
74
|DHE Connect | DHE Touch
Temperature limit via internal anti-scalding protection
(qualified contractor)
If required, the qualified contractor can set a permanent temper-
ature limit, for example in nurseries, hospitals, etc.
When supplying a shower, the appliance temperature setting
range must be adjusted by the qualified contractor to 55 °C or less.
Limiting it in this way prevents water from flowing out of the
appliance at temperatures which could cause injury.
+
Temperature limit via maximum function (user)
38
60
_
4
OFF 3s
You can adjust the temperature limit individually. The "Maximum"
symbol has a black background when the temperature limit is ac-
tivated (see "Settings" menu). "MAX" appears in the status display.
Dynamic anti-scalding protection
With the dynamic anti-scalding protection, after selecting a tem-
perature on the appliance or wireless remote control, the user
has automatic priority for setting the maximum temperature. The
priority is active for 2 minutes or until 2 minutes after the current
draw-off ends. After this, priority is automatically disabled.
During the priority period, you can reduce the set temperature or
increase it to a maximum of 43 °C using other wireless controls.
www.stiebel-eltron.com