INSTALLATION
Specification
Priority control with LR 1-A
2
1
1 Control cable to the contactor of the second appliance (e.g.
electric storage heater)
2 Control contact drops out when switching the instantaneous
water heater on.
www.stiebel-eltron.com
18.3 DHW output
The DHW output is subject to the power supply, the appliance
connected load and the cold water inlet temperature. The rated
voltage and rated output can be found on the type plate.
Connected load in kW
38 °C DHW output in l/min
Rated voltage
Cold water inlet temperature
380 V
400 V
415 V
16.2
19
21.7
18
21
24
19.4
22.6
25.8
24.4
27
29.1
DHE Connect | DHE Touch |
5 °C
10 °C
15 °C
20 °C
7.0
8.3
10.1
12.9
8.2
9.7
11.8
15.1
9.4
11.1
13.5
17.2
7.8
9.2
11.2
14.3
9.1
10.7
13.0
16.7
10.4
12.2
14.9
19.0
8.4
9.9
12.0
15.4
9.8
11.5
14.0
17.9
11.2
13.2
16.0
20.5
10.6
12.4
15.2
19.4
11.7
13.8
16.8
21.4
12.6
14.8
18.1
23.1
117