INSTALLATION
Standard installation
19
3 Nm
f Fit the pipes with flat gaskets onto the water connections.
f
f Open the 3-way ball shut-off valve or the shut-off valve in the
f
cold water inlet line.
www.stiebel-eltron.com
24
5 Nm
Making the electrical connection
WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
WARNING Electrocution
The connection to the power supply must be in the form
of a permanent connection in conjunction with the re-
movable cable grommet. Ensure the appliance can be
separated from the power supply by an isolator that dis-
connects all poles with at least 3 mm contact separation.
WARNING Electrocution
Ensure that the appliance is earthed.
Material losses
!
Observe the type plate. The specified rated voltage must
match the mains voltage.
f Connect the power cable to the mains terminal.
f
DHE Connect | DHE Touch |