Troubleshooting

16. Troubleshooting
WARNING Electrocution
To test the appliance, it must be supplied with power.
Note
When testing the appliance using the diagnostic traffic
lights, water must be flowing.
Indicator options for diagnostic lights (LED)
Red
Yellow
Green
Diagnostic traffic 
Fault
lights (draw-off 
mode)
No LED illuminates
Appliance does not heat up
Green flashing, yellow
No DHW
off, red off
112
|DHE Connect | DHE Touch   
Illuminates in the event of a fault
Illuminates in heating mode/flashes when output limit reached
Flashing: Appliance connected to power supply
Cause
One or more power supply phases are missing
PCB faulty
Appliance starting flow rate not reached; shower
head/aerator scaled up
Appliance starting flow rate not reached; strainer in
cold water inlet dirty
Flow meter not plugged in
Flow meter faulty or dirty
PCB faulty
Remedy
Check the fuses in the distribution board
Replace the function module
Descale/replace the shower head/aerator
Clean strainer
Check plug-in connection; correct if necessary
Replace flow meter
Replace the function module