Installing And Connecting Blower Control Panel (All Models) - Miller FILTAIR SWX-D Mode D'emploi

Table des Matières

Publicité

5-12. Installing And Connecting Blower Control Panel (All Models)

Single Extraction Arm
Installations
Dual Extraction Arm
Installations
OM-246877 Page 24
2
1
1
1
!
Installation must meet all Na-
tional, State, and Local Codes.
Have only qualified persons
make this installation.
!
Disconnect and lockout/tagout
input power before connecting
input conductors from unit.
Follow established procedures
regarding the installation and
removal of lockout/tagout de-
vices.
.
A dedicated 115 volt AC, 15 Amp
individual branch circuit protected
by time delay (type D) fuses or cir-
cuit breaker is required for each
blower assembly.
.
Also see Section 5-13 if installing
control panel for SWX-S models.
1
Blower Control Panel(s)
2
115 V, 15 A AC Power Supply
Remove cover from panel and remove
circuit breaker.
Install blower control panel near the fil-
ter cabinet. Reinstall circuit breaker in
panel.
Remove knockouts from panel box.
Install correct fittings in box to secure
conductor cable. Use the proper seal
or cord relief as required.
If using a flexible cord and plug con-
nection, use a 3-conductor, 14 AWG,
UL listed hard service cord or junior
hard service cord in accordance with
the National Electrical Code. The plug
should be rated for a minimum of 15
Amps and cord length should not ex-
ceed 15 ft (4.5 m).
For a permanent connection, remove
knockouts from panel box and install
1/2 in. conduit and connectors.
!
Do not make final electrical
connections until installation is
complete.
See the circuit diagram in Section 9 for
connection details.
Tools Needed:
Phillips No. 2
247 961 / 248 234

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Filtair swx-s

Table des Matières