2-5. Connecting Work Clamp and Gas/Air Supply
2
5
3
4
From Gas/Air Supply
Rear of Unit
2-6. Electrical Service Guide
NOTE
60 Hz Models
Input Voltage
Input Amperes At Rated Output
Max Recommended Standard Fuse Rating In Amperes
Min Input Conductor Size In AWG/Kcmil
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG/Kcmil
Reference: 1999 National Electrical Code (NEC)
1 Consult factory for circuit breaker applications.
2 "Time-Delay" fuses are UL class "RK5" .
3 "Normal Operating" (general purpose – no intentional delay) fuses are UL class "K5" (up to and including 60 amp), and UL class "H" ( 65 amp and
above).
OM-2220 Page 12
1
For any single or three phase voltage from 208 V to 575 V, the Amperes Input at
Rated Load Output is the same for 50 Hertz or 60 Hertz input power. For example,
the amperes input for 230 V, 50 Hz, single-phase input power is 33 amperes. The
amperes input for 230 V, 60 Hz, single-phase input power is also 33 amperes.
1
2
Time-Delay
Normal Operating 3
Tools Needed:
5/8, 1-1/8 in
Single Phase
208
230
460
575
36
33
16
13
45
40
20
15
50
50
25
20
10
10
14
14
72
89
138
215
(22)
(27)
(42)
(66)
10
10
14
14
1
Work Clamp
2
Workpiece
Connect work clamp to a clean,
paint-free location on workpiece, as
close to cutting area as possible.
.
Use only clean, dry air with 90
to 150 psi (620 to 1035 kPa)
pressure.
3
Gas/Air Inlet Opening
4
Hose
.
Hose must have a minimum
inside diameter of 3/8 in
(9.5 mm).
5
Teflon Tape
Obtain hose with 1/4 NPT right-
hand thread fitting. Wrap threads
with teflon tape (optional) or apply
pipe sealant, and install fitting in
opening. Route hose to gas/air
supply.
Adjust gas/air pressure according
to Section 3-2.
ST-802 185 / Ref. SB-192 441
Three Phase
208
230
460
575
21
20
9
25
20
10
30
30
15
12
14
14
87
69
275
429
(27)
(21)
(84)
(131)
12
14
14
8
10
10
14
14