5-13. Installing Cleaning System Control Panel (SWX-S Self-Cleaning Models Only)
SWX-S Self-Cleaning Fume Extractor
With Dual Extraction Arms
2
!
Installation must meet all National
State, and Local Codes. Have only
qualified persons make this instal-
lation.
!
Disconnect and lockout/tagout in-
put power before connecting input
conductors from unit. Follow estab-
lished procedures regarding the in-
stallation and removal of lockout/
tagout devices.
.
A 115 volt AC, 15 Amp individual
branch circuit protected by time delay
(type D) fuses or circuit breaker is re-
quired.
2
1
1
Cleaning System Control Panel
2
115 V, 15 A AC Power Supply
3
Filter Cabinet Junction Box
Install control panel near the filter cabinet.
.
Install control panel within 40 ft (12 m)
of filter cabinet. Clear tubing for control
panel gauge must not exceed 40 ft (12
m) in length.
Drill holes for fittings in the panel box. In-
stall correct fittings to secure conductor
cable. Use the proper seal or cord relief as
required.
Tools Needed:
Phillips No. 2
247 867 / 248 234 / 248 235
For a permanent connection, use 1/2 in. (12
mm) conduit and drill 7/8 in. (22 mm) clear-
ance holes for the fittings.
If using a flexible cord and plug connection,
use a 3-conductor, 14 AWG, UL listed hard
service cord or junior hard service cord in
accordance with the National Electrical
Code. The plug should be rated for a minim-
um of 15 Amps and cord length should not
exceed 15 ft (4.5 m).
!
Do not make final electrical connec-
tions until installation is complete.
See the circuit diagram in Section 9 for con-
nection details.
OM-246877 Page 25