5-4. Installing Filter Cabinet And Blower Assembly Mounting Brackets
.
See ceiling height requirements
in Section 4-3D.
Blower Mounting Bracket (6 Holes)
Recommended Height
7 ft Arm: 8 ft (2.4 m)
10 ft Arm: 8 ft (2.4 m)
12 ft. Arm: 9 ft (2.75 m)
Telescopic Arm: 8 ft (2.4 m)
!
Only qualified persons should in-
stall, operate, maintain, and repair
this unit.
!
Installation must meet all National,
State, and Local Codes − have only
qualified persons make this installa-
tion.
!
Do not use this equipment to sup-
port personnel, large tools, or other
material.
!
Do not damage electrical wiring and
other utilities when drilling into wall
or other structural support.
!
Be sure the mounting hardware and
the wall or other structure will sup-
port the weight of the equipment.
42 in. (107 cm) Minimum
Recommended For Filter Removal
11 in.
28 cm
26 − 38 in.
(66 − 96 cm)
!
Use only mounting hardware spe-
cifically designed for the structure
or material supporting the equip-
ment. Follow the recommendations
and installation guidelines provided
by the manufacturer of the mount-
ing hardware.
!
Install hardware in all six slots in the
mounting bracket.
!
Install bracket exactly as described.
For applications not covered in
these instructions, consult local
building codes and qualified per-
sons to ensure the equipment is ad-
equately supported.
Filter Cabinet
Mounting Bracket
(6 Holes)
Floor
Tools Needed:
1
Filter Cabinet Mounting Bracket
Select location for mounting bracket based
on the dimensions shown above. Use
bracket as a template to mark the six
mounting holes on the support structure.
Drill holes where marked.
.
See Figures 5-5 and 5-6 for hole pat-
tern layout drawings.
Secure bracket at all six hole locations with
mounting hardware capable of supporting
the weight of the equipment, and specific-
ally designed for attachment to the struc-
ture or material supporting the equipment.
274 964