4.2.3. guide pipes
As guide pipes, we recommend the use of galvanized steel pipes according to DIN EN 10255 or stainless steel
pipes according to DIN EN 10296-2 (tolerances in accordance with EN ISO 1127, Series 1). Depending on the
type of suspension unit, either one or two guide pipes are required. This does not affect installation.
guide pipe sizes and material versions
type
g 2/1r
DN 36/1r
DN 50/1r
DN 50/1rk
DN 50/2rk
DN 65/1rk
DN 65/2rk
DN 80/2rk
DN 100/2rk
DN 150l/2rk
DN 150S/2rk
DN 200/2r
DN 250/2r
DN 250S/2rk
Suspension units may not be used without guide pipes. otherwise, the pump will slip off the coupling
base. this causes the connection between the coupling flange and base to leak and the pump may be
damaged. to prevent this, the use of guide pipes is mandatory.
4.3.

Position

Together, the coupling base, guide pipe bracket and guide pipes form the suspension unit. This is installed in
the operating area and connected to the discharge-side pipe system.
the connected pipe system must be self-supporting. this means it must not be supported by the
coupling base.
The coupling flange is mounted on the discharge flange of the pump. It has guide claws to guide it along the
guide pipe so that the pump can be connected to the coupling base.
The coupling flange is automatically connected to the coupling base by the weight of the pump.
Number
1x
1x
1x
1x
2x
1x
2x
2x
2x
2x
2x
2x
2x
2x
24
Material
(*Outer Ø x wall thickness)
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
St 33
A2
A2
St 33
Size* in mm
42.4x2
42.4x2
42.4x2
26.9x2
26.9x2
26.9x2
26.9x2
42.4x2
42.4x2
42.4x2
60.3x3.65
42.4x2
42.4x2
60.3x3.65