Fichier shelfman.conf par défaut (suite)
EXEMPLE DE CODE 2-1
# SHORT_SEND_MSG_RESPONSE: This parameter of boolean type determines the
# type of response on the Send Message command provided by the Shelf
# Manager:required by the PICMG 3.0 R1.0 ECN-001 if TRUE or compatible with
# previous versions of the Shelf Manager if FALSE. Default is TRUE.
#
SHORT_SEND_MSG_RESPONSE = TRUE
# SDR_READ_RETRIES: This parameter sets the number of times the Shelf
# Manager retries the "Read Device SDR" command. Default is 3.
#
SDR_READ_RETRIES = 3
# RESERVATION_RETRIES: This parameter specifies the number of times the
# Shelf Manager retries the "Reserve Device SDR" command. Default is 10.
#
RESERVATION_RETRIES = 10
# TASKLET_RETRIES: This parameter specifies the number of times each Shelf
# Manager tasklet (activation, deactivation, getting information) is
# retried before finally giving up. The default is 3.
#
TASKLET_RETRIES = 3
# SHELF_FRU_IN_EEPROM: This parameter of boolean type tells the Shelf
# Manager if it should use SEEPROMs as the Shelf FRU Info storage. If set
# to FALSE the "/var/nvdata/shelf_fru_info" file contents are used. Default
# is TRUE.
#
SHELF_FRU_IN_EEPROM = TRUE
# LOCAL_SHELF_FRU: This parameter of boolean type specifies whether the
# Shelf Manager should create a local FRU#1 that will expose the Shelf FRU
# Info (obtained from the "/var/nvdata/shelf_fru_info" file). If the Shelf
# FRU Info is acquired from EEPROM as a result of the SHELF_FRU_IN_EEPROM
# set to TRUE then this parameter ignored. Default is TRUE.
#
LOCAL_SHELF_FRU = TRUE
# SHELF_FRU_TIMEOUT: This parameter specifies the time interval (in seconds)
# during which the Shelf Manager detects and reads the Shelf FRU Information
# source devices at initial startup. Default is 15 seconds.
#
SHELF_FRU_TIMEOUT = 15
# MIN_SHELF_FRUS: This parameter specifies the minimum number of valid and
Chapitre 2 Configuration de votre système
45