Exemple :
Actualisation effective : deux sources correspondent dans les informations sur les
FRU de l'étagère.
# clia shelf info_refresh
IPM Sentry Shelf Manager Command Line Interpreter
Read 0x20 # 2, size = 1024
Read 0x20 # 1, size = 1024
Found 2 Matching Shelf FRU Info
0x20 # 2, size = 1024 (data size = 775), "Valid" Shelf FRU,
"Matching"
0x20 # 1, size = 1024 (data size = 775), "Valid" Shelf FRU,
"Matching"
Shelf FRU Info was not changed
#
Unsuccessful refresh: both data sources contain non-matching or
invalid data.
# clia shelf info_refresh
IPM Sentry Shelf Manager Command Line Interpreter
Read 0x20 # 2, size = 1024
Read 0x20 # 1, size = 1024
No Matching Shelf FRU Info found
0x20 # 2, size = 1024 (data size = 293), "Invalid" Shelf FRU, "Non-
Matching"
0x20 # 1, size = 1024 (data size = 529), "Valid" Shelf FRU, "Non-
Matching"
Refresh was not done because system found only 1 (of 2) Matching
Shelf FRU info
#