none (0)
90 (0x5a)
251 (0xfb)
#
Identique à ce qui précède, mais avec une spécification explicite du LUN du capteur.
# clia sensor -v 9c 0:2
IPM Sentry Shelf Manager Command Line Interpreter
9c: LUN: 0, Sensor # 2 ("emulated temp")
196
Guide d'administration système du serveur Netra CT 900 • Janvier 2007
Lower Critical Threshold is Readable
Lower Non-Recoverable Threshold is Readable
Upper Non-Critical Threshold is Readable
Upper Critical Threshold is Readable
Upper Non-Recoverable Threshold is Readable
Lower Non-Critical Threshold is Settable
Lower Critical Threshold is Settable
Lower Non-Recoverable Threshold is Settable
Upper Non-Critical Threshold is Settable
Upper Critical Threshold is Settable
Upper Non-Recoverable Threshold is Settable
Unit Percentage: OFF (0), Unit Modifier: none (0), Unit Rate:
Analog Format: 2's complement (signed) (2)
Base Unit: degrees C (1), Modifier Unit: unspecified (0)
Linearization: linear (0), M = 1, B = 0, K1 = 0, K2 = 0
Tolerance = 0, Accuracy = 0, Accuracy EXP = 0
Analog Flags: 0x0
Nominal: 0 (0x00), Normal max: 0 (0x00), Normal min: 0 (0x00)
Sensor max: 127 (0x7f), Sensor min: 128 (0x80)
Upper Thresholds:
Non-Critical: 70 (0x46) Critical: 80 (0x50) Non-Recoverable:
Lower Thresholds:
Non-Critical: 3 (0x03) Critical: 0 (0x00) Non-Recoverable:
Hysteresis:
Positive: 2 (0x02), Negative 2 (0x02)
Type: Threshold (0x01), "Temperature" (0x01)
Belongs to entity: (0xd0, 0) [FRU # 0]
Assertion Mask: 0x7a95
Lower Non-Critical Going Low
Lower Critical Going Low
Lower Non-Recoverable Going Low
Upper Non-Critical Going High
Upper Critical Going High
Upper Non-Recoverable Going High
Upper non-critical threshold is comparison returned