Sun Microsystems Netra CT 900 Guide D'administration Et D'utilisation page 147

Table des Matières

Publicité

Numéro d'emplacement
12
13
14
Exemples :
Obtention d'informations standard sur toutes les cartes du système (lorsque seules
les cartes des emplacements physiques 1 et 14 sont présentes).
# clia board
IPM Sentry Shelf Manager Command Line Interpreter
Physical Slot # 1
82: Entity: (0xd0, 0x0) Maximum FRU device ID: 0x08
PICMG Version 2.0
Hot Swap State: M4 (Active), Previous: M3 (Activation In
Process), Last State Change Cause: Normal State Change (0x0)
82: FRU # 0
Entity: (0xd0, 0x0)
Hot Swap State: M4 (Active), Previous: M3 (Activation In
Process), Last State Change Cause: Normal State Change (0x0)
Device ID String: "IPM Sentry 6"
Physical Slot # 14
9c: Entity: (0xd0, 0x0) Maximum FRU device ID: 0x08
PICMG Version 2.0
Hot Swap State: M4 (Active), Previous: M3 (Activation In
Process), Last State Change Cause: Normal State Change (0x0)
9c: FRU # 0
Entity: (0xd0, 0x0)
Hot Swap State: M4 (Active), Previous: M3 (Activation In
Process), Last State Change Cause: Normal State Change (0x0)
Device ID String: "IPM Sentry 6"
#
Obtention d'informations détaillées sur une carte de l'emplacement physique 14.
# clia board -v 14
Physical Slot # 14
9c: Entity: (0xd0, 0x0) Maximum FRU device ID: 0x08
PICMG Version 2.0
Hot Swap State: M4 (Active), Previous: M3 (Activation In
Process), Last State Change Cause: Normal State Change (0x0)
Device ID: 0x00, Revision: 0, Firmware: 1.01, IPMI ver 1.5
Annexe A
Commandes CLI (Command Line Interface, interface de ligne de commande) de Shelf Manager
Adresse IPMB
94