EXEMPLE DE CODE 2-1
#
SEL_LOW_WATERMARK = 50
# MAX_SESSIONS: This parameter specifies the maximum number of simultaneous
#
#
MAX_SESSIONS = 32
# MAX_USERS: This parameter specifies the maximum number of IPMI users.
#
#
MAX_USERS = 32
# INITIAL_FAN_LEVEL: This parameter specifies the initial fan level that the
# Shelf Manager applies to fan trays. Usually fan levels values are in
# 0..15 range where 0 is the slowest, and 15 is the fastest possible fan
# speed. This parameter has an alias CTCA_INITIAL_FAN_LEVEL for CompactPCI
# systems. Default is 5.
#
INITIAL_FAN_LEVEL = 5
# MIN_FAN_LEVEL: This parameter specifies the minimal fan level that can be
# set by the Cooling Management. Default is 0.
#
MIN_FAN_LEVEL = 1
# PHYSICAL_SENSORS: This parameter of boolean type specifies whether the
# Shelf Manager should create IPMI sensors based on physical sensors hosted
# by ADM1026 and LM75. Default is TRUE.
#
PHYSICAL_SENSORS = TRUE
# POWER_UNLISTED_FRUS: This parameter of boolean type specifies whether the
# Shelf Manager should power up and activate FRU devices that are not listed
# in the Power Management table of the Shelf FRU Information. Default is
# TRUE.
#
POWER_UNLISTED_FRUS = TRUE
# AUTO_SEND_MESSAGE: This parameter of boolean type specifies whether to
# auto-convert RMCP requests targeting a non-ShM IPMB address into "Send
# Message" requests directed to that address. Default is TRUE.
#
AUTO_SEND_MESSAGE = TRUE
44
Guide d'administration système du serveur Netra CT 900 • Janvier 2007
Fichier shelfman.conf par défaut (suite)
IPMI sessions. Default 32.
Default is 32.