Shelf Manager Controlled Activation: Enabled
Delay Before Next Power On: 0.0 seconds
Hw Address: 45, FRU ID: 0xfe, Maximum FRU Power Capabilities: 200 Watts
Shelf Manager Controlled Activation: Enabled
Delay Before Next Power On: 0.0 seconds
Hw Address: 08, FRU ID: 0xfe, Maximum FRU Power Capabilities: 24 Watts
Shelf Manager Controlled Activation: Enabled
Delay Before Next Power On: 0.0 seconds
Hw Address: 09, FRU ID: 0xfe, Maximum FRU Power Capabilities: 24 Watts
Shelf Manager Controlled Activation: Enabled
Delay Before Next Power On: 0.0 seconds
Hw Address: 20, FRU ID: 0xfe, Maximum FRU Power Capabilities: 100 Watts
Shelf Manager Controlled Activation: Enabled
Delay Before Next Power On: 0.0 seconds
#
Affichage des informations de distribution électrique
●
L'exemple montre la commande et la sortie pour obtenir les informations sur la
distribution électrique de l'étagère.
# clia shelf pd
IPM Sentry Shelf Manager Command Line Interpreter
PICMG Shelf Power Distribution Record (ID=0x11)
86
Guide d'administration système du serveur Netra CT 900 • Janvier 2007
Version = 0
Feed count: 8
Feed 00:
Maximum External Available Current: 25.0 Amps
Maximum Internal Current: 25.0 Amps
Minimum Expected Operating Voltage: -40.5 Volts
Actual Power Available: 1012.500 Watts
Currently Used Power: 30.000 Watts
Feed-to-FRU Mapping entries count: 3
FRU Addr: 49, FRU ID: 0xfe
FRU Addr: 4b, FRU ID: 0xfe
FRU Addr: 4d, FRU ID: 0xfe
Feed 01:
Maximum External Available Current: 25.0 Amps
Maximum Internal Current: 25.0 Amps
Minimum Expected Operating Voltage: -40.5 Volts
Actual Power Available: 1012.500 Watts
Currently Used Power: 30.000 Watts