Dear Sir/Madam
Congratulations and thank you for choosing our product.
Please read this document carefully before you use this product in order to obtain the best performance in complete safety.
For further details or assistance, please contact the DEALER where you purchased the product or visit the TECHNICAL
ASSISTANCE CENTRES page on our website www.edilkamin.com.
NOTE
- After you remove the packaging, please inspect the unit for any damage or missing parts (cladding, remote control with display, "stay
cool" handle, warranty booklet, glove, technical data sheet, spatula, desiccant, hex key).
In case of anomalies please contact the dealer where you purchased the product immediately. You will need to present a copy of the
warranty booklet and valid proof of purchase.
- Commissioning/ testing
Commissioning and testing must be performed by an authorized Edilkamin Technical Assistance Centre. Failure to do so will void the
warranty. Commissioning, as specified in standard UNI 10683 Rev. 2005 (section "3.2") consists in a series of controls performed on
the installed stove in order to ascertain the correct operation of the system and its compliance to applicable regulations.
To locate the Technical Assistance Centre closest to you, please ask your local dealer, call our toll-free number, or visit our website
www.edilkamin.com.
- Incorrect installation, incorrect maintenance, or improper use of the product, shall relieve the manufacturer from any damage resul-
ting from the use of this product.
- the proof of purchase tag, necessary for identifying the stove, is located:
- on the top of the package
- in the warranty booklet found inside the firebox
- on the ID plate affixed to the back side of the unit;
This documentation must be saved for identification together with the valid proof of purchase receipt. The data contained therein must
be reported when requesting information and made available should servicing be required;
- All images are for illustration purposes only; actual products may vary.

SAFETY INFORMATION

THE THERMO-STOVE MUST NEVER BE MADE TO OPERATE WITHOUT WATER IN THE SYSTEM NOR AT A PRESSURE
OF LESS THAN 1 BAR.
IT CAN BE DAMAGED IF IT IS IGNITED WITH NO WATER IN THE SYSTEM.
• The thermo-stoves is designed to heat water by means of automatic combustion of pellets (wood with 6 mm diameter) in the hearth.
• The only risks that may derive from using the thermo-stoves pertain to non-compliance with the installation regulations, direct con-
tact with live electrical parts (internal), contact with the fire or hot parts, or foreign substances being put into the stove.
• Should components fail, the thermo-stoves is equipped with safety devices to guarantee its automatic shutdown.
• These are activated without any intervention required.
• In order to function correctly, the thermo-stoves must be installed in accordance with the instructions given herein.
• Whilst functioning, the door must never be opened. In fact, combustion is fully automatic and requires no manual intervention.
• Under no circumstances should any foreign substances be put into the hearth or the hopper.
• Do not use flammable products to clean the smoke discharge duct.
• Use a vacuum cleaner to clean the hearth and hopper, when COLD.
• The glass can be cleaned when COLD with a suitable product (e.g. GlassKamin) and a cloth. Do not clean when hot.
• Whilst the thermo-stoves is in operation, the exhaust pipes and door become very hot.
• Do not place anything that is not heat resistant near the thermo-stoves.
• NEVER use liquid fuel to ignite the thermo-stoves or rekindle the embers.
• Do not obstruct the external air inlets in the room where the stove is installed, nor those of the thermo-stoves itself.
• Do not wet the thermo-stoves and do not go near electrical parts with wet hands.
• Do not use reducers on the smoke exhaust pipes.
• The thermo-stoves must be installed in a room that is suitable for fire prevention and equipped with all that is required (power and
air supply and outlets) for the stove to function correctly and safely.
• The thermo-stoves must be kept in a room where the temperature is above 0 °C.
• Use appropriate anti-freeze additives for the water of the system.
• Ensure that the temperature of the return water is at least 45 °C.
Should ignition fail, DO NOT re-ignite until you have emptied the combustion chamber.
The undersigned EDILKAMIN S.p.a. with head office headquarters at Via Vincenzo Monti 47 - 20123 Milan - Italy - VAT T00192220192
Declares under its own responsability as follows:
The pellet Boiler-stoves illustrated below conforms to Regulation EU 305/2011 (CPR) and to the harmonised European Standard EN 14785:2006
WOOD PELLET BOILER-STOVES, trademark EDILKAMIN, called QUEBEC - TORONTO - MONTREAL - DETROIT - BOSTON - MIAMI
Year of manufacture:
Ref. Data nameplate
The pellet boiler illustrated below conforms to the Machinery Directive 2006/42/EC and to the harmonised European Standard EN 303-5:2012
WOOD PELLET BOILER, trademark EDILKAMIN, called OTTAWA - ATLANTA
Year of manufacture:
Ref. Data nameplate
The wood pellet Boiler-stoves QUEBEC - TORONTO - MONTREAL - DETROIT - BOSTON - MIAMI and pellet Boiler OTTAWA-
ATLANTA is in compliance with the requirements of the European directives:
2006/95/EEC - Low voltage directive
2004/108/EEC - Electromagnetic compatibility directive
EDILKAMIN S.p.a. will decline all responsability of malfunctioning or damage to the equipment in case of unauthorized
substitution, assembly or modifications of any sort on the said equipment on the part of non-EDILKAMIN personnel.
Declaration of performance (DoP - EK 051-059): Ref. data tag plate