Mimic panel
to turn on and off (hold down for 2") and to exit from the menu during programming
to access the menu during programming
to increase the various settings
to decrease the various settings
(pellet loading/reserve button)
press once to 'inform' the thermo-stoves memory that a 15 kg sack of pellets has been loaded, thereby allowing it to
keep track of the reserve.
(boiler setting button)
this button together with the +/- keys controls a secondary circuit, e.g. that of a boiler.
The right side of the display shows the temperature of any external storage tank/boiler (if the boiler sensor is connec-
ted). Press the 'boiler' button to see the set value. If the boiler sensor is not connected, dashes will appear instead of the
temperature (--- °C).
Left display
1st ignition
The first start up must, without fail, be performed by DEALER.
You must consult the DEALER in your area when igniting the stove for the first time, in order for the thermo-stoves to be calibrated
according to the type of pellets and installation conditions
The DEALER must also:
- Verify that the hydraulic system is correctly installed and is equipped with an expansion tank that is sufficiently large to guarantee
safety. The presence of a tank within the thermo-stoves does NOT guarantee appropriate protection from thermal expansion
occurring in the whole system.
- Connect the electrical power to the thermo-stoves and implement a cold test (to be carried out by the DEALER).
- Fill the system using the filling tap (it is recommended not to exceed a pressure of 1bar).
When filling, 'bleed' the pump and the relief tap.
Warning:
During the initial start up phase, use the manual valves (V1-V2-V3)
beneath the cast iron cover to perform the air/water purging operation.
This operation must also be repeated during the first days of use and
whenever the system is reloaded, even partially. The presence of air within
the pipelines can hinder the unit's proper functionality. Rubber tubes are
supplied with valves V1 and V2 to facilitate relief operations.
First ignitions.
There may be a slight smell of paint the first few times it is ignited, however, this will disappear quickly.
Before igniting you must check:
• that installation is correct / • the power supply/ • that the door closes properly to a perfect seal
• that the combustion chamber is clean/ • that the display is on stand-by (time and temperature set).
INSTRUCTIONS FOR USE
Pellet load/reserve
Remote control receiver
Boiler
Right display
V2
42
V1
V3