TECHNICAL AND HEATING SPECIFICATIONS
Hopper capacity
Approx. overall efficiency
Rated power
Water heating power
Min./max. autonomy
Fuel consumption min./max.
Minimum draught
Max. pressure
Operating pressure
Smoke output temperature from test EN14785
CO emission (13% O2)
Weight including packing
Heating capacity *
Diameter of smoke extract duct male thread
* The heatable room dimensions are calculated on the basis of pellets with an lhv of at least 4300 kcal/kg and home insulation in compliance
with Italian law 10/91, and subsequent changes together with an expected heat output of 33 Kcal/m³ per hour.
It is also important to consider the position of the thermo-stoves in the room to be heated.
A LOT DEPENDS ON THE EFFICIENCY OF THE SYSTEM TERMINALS (heaters).
N.B.
1) Bear in mind that external devices may cause interference.
2) Warning: work on live components, maintenance and /or checks must be performed by qualified personnel.
(Before carrying out any maintenance, disconnect the device from the mains power supply)
ELECTRICAL CHARACTERISTICS
Power supply
On/off switch
Average power consumed
Average power consumed upon ignition
Radio control / Remote control frequency
Main power supply protection **
Electronic control board protection
The data shown above is purely indicative.
EDILKAMIN reserves the right to make changes to these products to improve their performance with no prior warning.
SAFETY DEVICES
THERMOCOUPLE:
placed at the smoke outlet to detect the temperature. Turns the thermo-stoves on and off and
controls its operation based on defined parameters.
VACUUM GAUGE (electronic pressure sensor):
positioned on the smoke extractor, which detects the vacuum value (compared to the
installation environment) in the combustion chamber.
WATER SAFETY THERMOSTAT:
trips when the temperature inside the thermo-stoves is too high.
It stops pellet loading, causing the thermo-stoves to go out. Reset manually.
TANK SAFETY THERMOSTAT:
trips when the temperature inside the thermo-stoves is too high.
It stops pellet loading, causing the thermo-stoves to go out.
SERIAL PORT
The Dealer can install an optional on the AUX outlet for controlling the process of switching on and off (e.g. telephone remote,
local thermostat), located at the rear oh the stove. Can be connected via special optional trestle (code 640560).
BACKUP BATTERY
A backup battery is found on the control board (3-Volt CR 2032 battery). Its malfunction is indicated with the following messages
(not considered a defect but due to normal wear-and-tear): "Battery Check".
For more detailed information, please contact the DEALER who has performed the first 1st ignition.
FEATURES
QUEBEC/ TORONTO/MONTREAL DETROIT/ BOSTON/MIAMI
60
93,3
24
21
11,5 / 37,5
1,6 / 5,3
12
3
1,5
114
0,011
390 / 370 / 360
390 / 370 / 359
625
10
30
OTTAWA
60
100
93,2
91,7
32,6
24
29,3
24
8 / 28
17 / 58
2,1 / 7,4
1,7 / 5,7
2,1 / 7,4
12
12
3
3
1,5
1,5
142
138
0,012
0,056
355
850
625
10
10
230Vac +/- 10% 50 Hz
yes
120
400
Radio waves 2.4 GHz / Infrared
** Fuse 2A, 250 VAC 5x20
** Fuse 2A, 250 VAC 5x20
FUSE**
two fuses are inserted in the soc-
ket with switch, located on the
back of the stove, one of which
operational and the other is held
in reserve.
ATLANTA
100
kg
92,3
%
32,3
kW
32,3
kW
14/ 48
hores
kg/h
12
Pa
3
bar
1,5
bar
143
°C
0,012
%
355
kg
840
m
3
10
cm
W
W
**