Technical Data - SICK PAC50 Notice D'instruction

Masquer les pouces Voir aussi pour PAC50:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operating Instructions

9 Technical data

9.1 Features
Medium
Compressed air quality
Zero point adjustment
Measuring ranges
Process temperature
Switching outputs
7 8
O p e r a t i n g I n s t r u c t i o n s | S I C K
9 Technical data
Dry compressed air
According to ISO 8573-1:2010
Max. particle size: ≤ 40 μm
Oil content: 0–40 mg/m
3
The pressure dew point must be at least 15°C below the ambient and medium tem-
peratures and must not exceed 3°C
Max. 5 % of span
–1 bar ...0 bar; –1 bar ...+1 bar; 0 bar ... +6 bar; 0 bar ... +10 bar; –1 ... 10 bar
0 °C to 60 °C
Depending on variant: 1 or 2 transistor switching outputs
PNP/NPN/push-pull can be set (in versions with IO-Link: switching output 1: option of
switching between IO-Link/PNP, and switching output 2: between PNP/NPN/push-pull)
Function: normally open/normally closed, window and hysteresis function freely
adjustable
Switching voltage: Supply voltage L
Max. switching current per switching output: 100 mA
Switching delay: 0 s to 50 s (adjustable)
Switching time ≤ 5 ms
Versions with IO-Link: IO-Link version 1.1
– 2 V [V DC]
+
8017612/YSZ4/2016-02-09 | PAC50
Subject to change without notice
PAC50

Publicité

Table des Matières
loading

Table des Matières