Operating Instructions
7.4.2.
Menu structure, description of the parameters, and factory settings (Figure 14)
Display mode
(2 s)
Programming
mode
SP1/FH1
Value
RP1/FL1
Value
SP2/FH2
Value
RP2/FL2
Value
EF
6 8
O p e r a t i n g I n s t r u c t i o n s | S I C K
3 Transport, packaging, and storage
RES
YES/NO
DS1
Value
DR1
Value
DS2
Value
DR2
Value
OU1
PARA
Description
Switching point 1/upper window limit 1
Reset point 1/lower window limit 1
Switching point 2/upper window limit 2 (if second switching output
is available and not configured in diagnosis mode)
Reset point 2/lower window limit 2 (if second switching output
is available and not configured in diagnosis mode)
Resets the set parameters to the factory settings (also resets the
saved HIGH and LOW values)
Switching delay 1
Reset delay 1
Switching delay 2 (if second switching output is available)
Reset delay 2 (if second switching output is available)
Switching function, switching output 1:
Hysteresis function, normally open: HNO
Hysteresis function, normally closed: HNC
Window function, normally open: FNO
Window function, normally closed: FNC
8017612/YSZ4/2016-02-09 | PAC50
Subject to change without notice
PAC50