14
12 Technical specifications
Input data
Measuring ranges
Overload pressures
Burst pressure
Mechanical connection
Torque value, recommended
Parts in contact with medium
Output data
Switching outputs
Analogue output, permitted load resistance
Accuracy to DIN 16086,
Max. setting
Temperature kompensation zero point
Temperature kompensation range
Repeatability
Reaction time
Long-term drift
Environmental conditions
Compensated temperature range
Operating temperature range
Storage temperature range
Fluid temperature range
-mark
Vibration resistance to
DIN EN 60068-2-6 at 10 .. 500 Hz
Shock resistance to
DIN EN 60068-2-27 (11ms)
Protection class to DIN EN 60529
Other data
Supply voltage
Current consumption
Display
Weight
Note:
Reverse polarity protection of the supply voltage, excess voltage,
override, short circuit protection are provided.
FS (Full Scale) = relative to the complete measuring range
1)
With mounted female connector having the corresponding protection class
Status: 19.09.2018
16 | 40 | 100 | 250 | 400 | 600 bar
32 | 80 | 200 | 500 | 800 | 1000 bar
200 | 200 | 500 | 1000 | 2000 | 2000 bar
G1/4 A ISO 1179-2
20 Nm
Mech. connection: Stainless steel
Seal: FPM
1 or 2 PNP transistor outputs
Switching current: max. 1.2 A per switch output
Switching cycles: > 100 million
4 .. 20 mA
≤ ± 0.5 % FS typ.
≤ ± 1 % FS max.
≤ ± 0.02 % FS / °C typ.
≤ ± 0.03 % FS / °C max.
≤ ± 0.02 % FS / °C typ.
≤ ± 0.03 % FS / °C max.
≤ ± 0.5 % FS max.
approx. 10 ms
≤ ± 0.3 % FS typ. / year
-10 .. +70 °C
-25 .. +80 °C
-40 .. +80 °C
-25 .. +80 °C
EN 61000-6-1 / 2 / 3 / 4
≤ 10 g
≤ 50 g
1)
IP 65
20 .. 32 V DC
approx. 100 mA (inactive switch output)
3-digit, LED, 7 segment, red,
height of digits 9.2 mm
̴ 300 g
HYDAC ELECTRONIC GMBH
load resistance max. 400 Ω
Part No.: 669648 E
EDS 300