EDS 300
6
Operating keys on the membrane keypad
7
Digital display
After switching on the supply voltage, the unit briefly displays "EdS" and then
displays the actual pressure.
In the basic settings the display can be altered. For example, the maximum value can be
permanently displayed. This is the highest pressure which has been recorded since the unit was
switched on or was last re-set. A switching point can likewise be permanently displayed or the
display can be switched off. Depending on the setting, "TOP", "S.P.1", "S.P.2" or "OFF" appears
briefly on the display following the switch-on message.
The actual pressure can be displayed briefly by pressing the ▼ or the ▲ key. This causes the
maximum value to be re-set.
NOTE:
• If the actual pressure exceeds the nominal pressure of the unit, it can no longer be
displayed and the display begins to flash.
• If the actual pressure is below 1 % of the nominal range, then 0 is displayed.
Status: 19.09.2018
3-digit digital display
Keys for setting switching points,
switch-back points and additionals
functions
HYDAC ELECTRONIC GMBH
7
Part No.: 669648 E