16 Technical Data
Input data
Sensor type
Probe length
Measuring range
Max. speed of change of the fluid level
Repeatability
Switching point accuracy
Temperature (optional)
Sensor type
Measuring range
Accuracy
Reaction time (t
)
90
Output data
Output signals
Analogue output
Selectable in case of universal output
Switching outputs
Version
Assignment
Switching current
Switching cycles
Parameterisation
Ambient conditions
Compensated temperature range
Operating temperature range
Storage temperature range
Fluid temperature range
- mark
Vibration resistance according to
DIN EN 60068-2-6 (0 .. 500 Hz)
Shock resistance according to
DIN EN 60068-2-29 (1 ms)
Protection class to IEC 60529
Version 2014/12/11
Capacitive level sensor
250; 410; 520; 730 mm
170; 290; 390; 590 mm
40; 60; 80; 100 mm/s
≤ ± 2 % FS *
≤ ± 2 % FS
Semi-conductor sensor
-25 .. +100 °C
± 1.5 °C
180 s
Output 1: PNP transistor output
Output 2: can be configured as PNP transistor
switching output or as analogue output
4 .. 20 mA
0 .. 10 V
Corresponds to measuring range selected
Transistor output PNP
Programmable as N/O or N/C
On version with temperature measurement
user-selectable temperature or fluid level
SP1: max. 0.1 A
SP2: max. 0.25 A
> 100 million
Via IO-Link interface, see chap. 8
or push buttons on the ENS 3000
0 .. +60 °C
0 .. +60°C
-40 .. +80 °C
0 .. +60 °C
EN 61000-6-1 / 2 / 3 / 4
≤ 5 g
≤ 25 g
IP 67
HYDAC ELECTRONIC GMBH
ohmic resistance ≤ 500 Ω (R
ohmic resistance ≥ 1 kΩ (R
Part No. 669898
page 24
)
L
)