EDS 3000 IO-Link
17 Technical Data
17.1 EDS 3000 WITH CERAMIC SENSOR CELL;
ABSOLUTE AND RELATIVE PRESSURE UP TO 16 BAR
Input data
Measuring ranges for
ceramic sensor at absolute pressure
Overload range
Burst pressures
Measuring ranges for
ceramic sensor at relative pressure
Overload range
Burst pressures
Mechanical connection
Torque value
Parts in contact with fluid
Output data
Output signals
Accuracy to DIN 16086
Max. setting (display, analogue output)
Repeatability
Temperature drift
Analogue output
Signal
Switching outputs
Version
Switching current
Switching cycles
Reaction time
Long term drift
Parameterisation
Ambient conditions
Compensated temperature range
Operating temperature range
Storage temperature range
Fluid temperature range
mark
Vibration resistance according to
DIN EN 60068-2-6 (0 .. 500 Hz)
Shock resistance according to
DIN EN 60068-2-29 (11 ms)
Protection class to IEC 60529
Edition: 2014-11-06
1; 2.5 bar
3; 8 bar
5; 12 bar
-1..1; 1; 2.5; 6; 10; 16 bar
3; 3; 8, 18, 30, 48 bar
5; 5; 12; 30; 50; 80 bar
G1/4 A ISO 1179-2 (DIN 3852)
Threaded port DIN 3852-G1/4
20 Nm
Mechanical connection: Stainless steel
Sensor cell: Ceramic
Seal: FPM / EPDM (as per model code)
Output 1: PNP transistor output
Output 2: can be configured as PNP transistor
switching output or as analogue output
≤ ± 0.5 % FS typ.
≤ ± 1 % FS max.
≤ ± 0.25 % FS max.
≤ ± 0.025 % FS / °C max. zero point
≤ ± 0.025 % FS / °C max. range
selectable:
4 .. 20 mA
0 .. 10 V
PNP transistor output
Programmable as N/O or N/C
SP1: max. 0.1 A ;
> 100 million
< 10 ms
≤ ± 0.3 % FS typ. / year
Via IO-Link interface, see chap. 7
or push buttons on the EDS 3100 / 3300
-10 .. +70 °C
-25 .. +80°C
-40 .. +80 °C
-25 .. +80 °C
EN 61000-6-1 / 2 / 3 / 4
≤ 10 g
≤ 50 g
IP 67
HYDAC ELECTRONIC GMBH
load resistance max. 500 Ω
load resistance min. 1 kΩ
SP2: max. 0.25 A
Part No.: 669897 E
17