ENS 3000 IO-Link
6
Operating keys of the ENS 3000
The
and
keys can be used to select the next or previous menu options. They can
also be used to set values.
• One step back in menu
• Decrease value
7
Operation Modes
7.1
SIO MODE
After start-up, the level switch is in SIO mode (standard I/O mode). In this mode, Pin 4
serves as a switch output.
The centre LED is constantly lit.
According Chapter 11 (basic settings, main menu and extended functions) the behaviour
of the ENS 3000 can be adjusted to the corresponding application.
7.2
SDCI MODE
Via a connected IO-Link master the level switch can be switched to the SDCI mode
(Single-drop digital communication interface for small sensors and actuators) by means of
a wake-up signal. In this mode, Pin 4 serves as a communication pin. The master is able
to communicate with the level switch in order to change parameters or to read out
measured values.
The centre LED flashes.
Version 2014/12/11
HYDAC
°C °F
SP1
cm
mode
Keys for adjustment of the switch
points, switch-back points and
additional functions
HYDAC ELECTRONIC GMBH
Display of
Temperature unit
4-digit
Digital display
SP2
LED-Display of the active
switching point
LED display constantly lit: Switch in SIO mode
LED display flashing: Switch in SDCI mode
• One step forward in menu
• Increase the value
page 11
Part No. 669898