7.3 Measurement cards / transducer connection

7.3.1 PX455

SG full or half bridges / inductive full or half bridges / LVDT / po-
tentiometric sensors / piezoresistive sensors / TEDS (0-wire)
SG and inductive full bridges
wh
Measurement signal (+)
bk
Bridge excitation voltage (−)
rd
Measurement signal (−)
bu
Bridge excitation voltage (+)
gn
Sense lead (+)
gy
Sense lead (−)
ye
Cable shield
Transducer
connection
plug terminal
Cable color code for HBM transducer cables:
wh= white; bk= black; bu= blue; rd= red; ye = yellow; gn= green; gy= gray
Fig. 7.1: PX455 plug terminal pin assignment
SG and inductive half bridges
1
2
4
3
'
3
'
2
Hsg.
LVDT transducers
Hsg.= housing
Electrical connection
0-wire TEDS see
Section 7.6.3
wh
Measurement signal (+)
bk
Bridge excitation voltage (−)
bu
Bridge excitation voltage (+)
gn
Sense lead (+)
gy
Sense lead (−)
ye
Cable shield
Measurement signal (+)
Bridge excitation voltage (−)
Bridge excitation voltage (+)
Measurement signal (−)
Cable shield
Sense lead (+)
Sense lead (−)
A3257−2.0 en/de/fr
1
2
3
'
3
'
2
Hsg.
Hsg.= housing
1
2
3
4
Hsg.
'
3
'
2
Hsg.= housing