Degree Of Protection / Housing / Shielding Design - HBM PMX Manuel D'emploi

Masquer les pouces Voir aussi pour PMX:
Table des Matières

Publicité

24
5

Degree of protection / housing / shielding design

The degree of protection given in the specifications indicates the suitability of
the device for various ambient conditions and also the protection it gives
people against potential risks when they are using it. The letters IP (Interna-
tional Protection), which are always present in the designation, are followed
by two digits. These indicate which degree of protection a housing offers
against contact or foreign bodies (first digit) and moisture (second digit).
All PMX modules and the basic device are designed with degree of protection
IP20 (as per DIN EN 60529).
IP
Code index
2
New Greenline shielding design:
To improve electromagnetic interference protection, HBM has developed an
effective measure, the Greenline shielding design. The shield is connected to
the connector housing. Appropriate routing of the cable shield means that the
entire measuring chain is completely enclosed by a Faraday cage.
Fig. 5.1: Greenline shielding design
2
Degree of protection
against
contact and foreign
bodies
Protection against
contact with fingers,
protection against
foreign bodies
with > 12 mm
wh
bk
rd
bu
gn
gy
ye
Degree of protection
0
Code index
Degree of protection
against water
0
No water protection
A3257−2.0 en/de/fr

Publicité

Table des Matières
loading

Table des Matières