92
8
Extreme value (peak)
Function
Inputs
Outputs
Parameters
Default
Exception handling
9
Characteristic (21 data points) (characteristic21)
Function
Inputs
Outputs
Parameters
Default
Exception handling
Can be used, e.g. for the limiting of values or absolute value formation.
Jumps in the characteristic curve are permissible, i.e. x1=x2 is possible. The
output jumps from y1 to y2 at this point.
If input < x0 , then output out0 = y0.
If input > than the biggest point used x
Maximum, minimum or peak-to-peak value
Reset via digital input (edge-controlled) Hold via digital in-
put (level-controlled)
- Input in0
- Digital Reset input
- Digital Hold input
Extreme value out0
- Type [Maximum, Minimum, Peak-to-Peak]
- Inverting of the Hold input
Digital inputs: Not used
If the input is marked as invalid (Invalid bit), the output is
also marked as invalid.
The extreme value is nonetheless determined and output .
Non-linear characteristic
Characteristic input in0
Characteristic output out0
- Number of data points used (2 .. 21) nbrPoints
- Up to 21 data points (x0|y0) ... (x20|y20)
Points 0 and 1: (-1000|-1000) (1000|1000)
If the input is marked as invalid (Invalid bit), the output is
also marked as invalid.
The output value is nonetheless determined and output .
, then output out0 = y
n
Type: Maximum
Inverting: Off
nbrPoints: 2
Quick Start
.
n
A3257−2.0 en/de/fr