5

Electrical connection

Reference torque measuring discs are equipped with a fixed 6 wire
connection cable (six wire circuit) with free ends. A connector assembly is
possible on request (see Chapter 7.)
Extension cables should be shielded and low capacitance. HBM provides
cables 1−KAB0304A−10 (ready made) and KAB8/00 2/2/2 (by the meter, can
also be supplied with fitted appliance connector) especially for this.
The pin assignment for HBM measuring amplifiers can be found in the
following table:
Connection
Measurement signal (+U
Excitation voltage (−U
Excitation voltage (+U
Measurement signal (−U
Sensor circuit (−)
Sensor circuit (+)
Shielding connected to enclosure
ground
Table 5.1: Pin assignment
The measuring amplifier pin assignments with soldered or clamped
connection can be found in the documentation of the particular amplifier.
A0162 7.0 en/de/fr
Wire colour
)
White
A
)
Black
B
)
Blue
B
)
Red
A
Gray
Green
Yellow
Connection to a measuring amplifier
with
15 pin
Sub D connector
8
5
6
15
12
13
1
19
7 pin
connector
A
B
C
D
G
F
E
HBM