Technical data
7.4.2 control medium
In conjunction with pneumatic control units (positioner or process
controllers), pilot air according to DIN ISO 8573-1 must be used:
• Class 3 (for water content)
• Class 5 (for dust and oil content).
The specification is described in detail in the operating
instructions of the respective positioner / process controller
in the chapter entitled "Technical data".
7.4.3 pressure ranges
pilot pressure range
on controlled operation
5)
actuator
Orifice dn
size
[mm]
ø 50 mm
15 – 25
ø 70 mm
15 – 32
ø 90 mm
25 – 50
40 – 50
ø 130 mm
65
Tab. 3:
Pilot pressure range on controlled operation
To ensure reliable operation with pneumatic control units (posi-
5)
tioner or process controller), observe the permitted minimum
and maximum pilot pressure!
Type 2300
pilot pressure range
[bar]
5)
cfa
cfB
3.4 – 5.5
3.3 – 5.1
2.6 – 5.5
2.6 – 5.2
3.3 – 5.5
1.8 – 2.5
3.3 – 5.6
1.9 – 2.7
4.6 – 5.6
1.9 – 2.7
maximum pilot pressure for valves
without pneumatic control unit
actuator size actuator material
ø 50 mm
ø 70 mm
PPS
ø 90 mm
ø 130 mm
Tab. 4:
Pilot pressure for valves without pneumatic control unit
Observe the maximum pressure range according to the type
6)
label!
english
max. permitted pilot
pressure
6)
10 bar
7 bar