Battery Care
!
UNDER NORMAL DAILY USAGE:
Re-charge the machine FULLY after each use regardless of machine operation time.
Do not leave the machine in a discharged state.
Periodically inspect the battery connections for tightness and corrosion.
Charging Light Sequence 10 & 20Amp On-board Charger
10Amp
Signal (LED)
Red LED on
Orange LED on
Green LED on
Red LED flashing
followed by Pause
Orange LED flashing
20Amp
Signal (LED)
Red LED on
Orange LED on
Green LED on
Red LED flashing
followed by Pause
NOTE: Check machine rating label for correct charger amperage
Under abnormal use;
i.e. leaving the machine without charging for a period of time, we advise that you
follow these steps:
If the machine will be standing unused for a period of 30 days or more, then batteries
must be fully charged and battery fuse removed using the maxi fuse-puller provided, prior
to this period.
Batteries should be re-charged every three
months.
Charge fully the day before you start using the
machine again.
30
www.numatic.co.uk
To ensure your machine remains at its maximum efficiency
and prolong your battery life, please follow the simple steps below:
First Phase (constant current Mode)
Second Phase (Constant Voltage Mode)
Third Phase (Constant Voltage Mode) Charge Complete
Charging System Error
Unsuitable battery or charging malfunction, safety timer exceeded,
Internal short circuit, disconnect from power supply, switch power supply,
OFF then ON, to restart the charging cycle
Battery not connected
First Phase (constant current Mode)
Second Phase (Constant Voltage Mode)
Third Phase (Constant Voltage Mode) Charge Complete
Cooling Fan Locked > 1 flash between pause
Over Voltage Protection / Output Short Circuit / Battery Reverse Polarity > 2 flashes between pause
Over Temperature Protection > 3 flashes between pause
Charge Time has exceeded 10 hrs during phase 1 or 2 > 4 flashes between pause
Meaning