Table des Matières

Publicité

To ensure your machine remains at its maximum efficiency and prolong your battery life,
please follow the simple steps below:
Under normal daily usage:
Recharge batteries after each use regardless of machine operation time.
Recharge the machine fully after its
last use. Do not leave the machine in a
discharged state.
Signal (LED)
Red LED on
Orange LED on
Green LED on
Red LED flashing
followed by Pause
Under abnormal use; i.e. leaving the machine without charging
for a period of time, we advise that you follow these steps:
If the machine will be standing unused for a period of 30 days or more, then
batteries must be fully charged and battery fuses removed using the Maxi
fuse-puller provided, prior to this period.
Batteries should be recharged every three months.
Charge fully the day before you start using the machine again.
Periodicly inspect the battery connectioins for tightness and corrosion
Meaning
First Phase (constant current Mode)
Second Phase (Constant Voltage Mode)
Third Phase (Constant Voltage Mode) Charge Complete
Cooling Fan Locked > 1 flash between pause
Over Voltage Protection / Output Short Circuit / Battery
Reverse Polarity > 2 flashes between pause
Over Temperature Protection > 3 flashes between pause
Charge Time has exceeded 16 hrs during phase 1 or 2 >
4 flashes between pause

Battery Care

30
www.numatic.co.uk

Publicité

Table des Matières
loading

Table des Matières