Setting The Time Period; Connection Example - Sony HSR-X216 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Preparations
1
Turn the Jog dial to highlight the MODE line and
turn the Shuttle dial clockwise.
NO USE (the current setting) flashes.
2
Turn the Jog dial to set to USE and turn the Shuttle
dial clockwise.
3
Set when to switch to summer (daylight savings)
time on the ON line.
WEEK: What day of which (first, second, third,
fourth, or last) week in the specified month on
which to switch
MONTH: Month in which to switch
TIME: Time (hours:minutes) when to switch
4
Similarly set when to return to the standard time on
the OFF line.
When the settings are completed
Press the EXIT/OSD button to exit the menu.
Adjusting the clock of another device
The built-in clock of another connected device can be
set using the ALL terminal on the rear panel.
Set the hours and minutes for ADJUST. TIME of
EXT. CLOCK SET.
The output at the ALL terminal will drop to
0 V at the time you specify here.

Connection example

HSR-X216/X209P/X216P
MIC
12
13
14
15
16
RS485
A
B
RS-232C
DO NOT CONNECT
PHONE LINE
HSR-X200 series,
SVT-960 series, etc.
RS-232C
62
(GB)
-AC IN
ALARM IN
C 1 2 3
4 5 6 7 8 9
10 11 12 13
14
15 16
SENSOR ALARM OUT
MON REC
ALARM
WARNING
ALARM
C R1 R1 ALL OUT RESET
FULL
FULL C
ON
RS485
TERMINATE
OFF
C
ALL
CLOCK
COM
IN
NON REC OUT
WARNING OUT
ALARM
CLOCK
RESET
ALARM
COM
IN
OUT
COM
IN
OUT
FULL
FULL
-AC IN
COM
COM
COM
IN OUT
COM
COM
A
B
REMOTE
SW OUT
SERIES
RS485
RS485
TERMINATE
ON
OFF

Setting the Time Period

You can perform settings for various operations, such
as the automatic switching operation, the mask
function, and the activity sensor operation, individually
for each quarter of a day (ex. night, morning, daytime,
and evening).
Two settings A and B are possible.
Perform settings on the submenu 2. TIME PERIOD
SET of the main menu 1. INITIAL SET.
1
Select 1. INITIAL SET from the main menu.
2
Select 2. TIME PERIOD SET from the submenu.
The TIME PERIOD SET menu appears.
<TIME PERIOD SET>
TIME PERIOD
T1
TIME PERIOD A
00:00 00:00 00:00 00:00
TIME PERIOD B
00:00 00:00 00:00 00:00
SELECT TIME PERIOD
SEQUENCE
TIME PERIOD A
MASK
TIME PERIOD A
ACTIVITY SENSOR
TIME PERIOD A
3
Specify the time period.
1) Select TIME PERIOD A, then turn the Shuttle
dial clockwise.
The two left figures of T-1 flash.
2) Enter each hour figure of the beginning time
(24-hour display) for the period T-1 with the Jog
dial, then turn the Shuttle dial clockwise.
The minute figures for T-1 flash.
3) Enter each minute figure of the beginning time
for the period T-1 with the Jog dial, then turn the
Shuttle dial clockwise.
The two left figures of T-2 flash.
4) Specify the beginning time of T-2, T-3, and T-4
in the same manner.
Perform settings of T-1 to T-4 for the time period
setting B.
4
Select the time-period setting A or B for each
operation, such as the automatic switching
operation (
page 25(GB)
) and the activity sensor operation (
25(GB)
).
37(GB)
When the settings are completed
Press the EXIT/OSD button to exit the menu.
T2
T3
T4
), the mask function (
page
page

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hsr-x209pHsr-x216p

Table des Matières