Connections For Remote Control And Associated Settings; Connection Examples - Sony HSR-X216 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Connections and Settings
Connections for Remote Control
and Associated Settings
Remote control via the RS-232C or RS-485 interface,
or with a special circuit connected to the REMOTE
terminal, is possible

Connection examples

RS-232C connector
HSR-X216/X209P/X216P
MIC
ALARM IN
12
13
14
15
16
C 1 2 3
SENSOR ALARM OUT
RS485
A
B
RS-232C
ON
RS485
TERMINATE
OFF
DO NOT CONNECT
PHONE LINE
RS-232C
to RS-232C
(D-sub 9-pin)
9-pin D-sub cable
(optional)
Pin arrangement of the RS-232C connector
(D-sub 9-pin)
1
6
Pin No. Signal
Function
2
RxD
Data reception
3
TxD
Data transmission
5
GND
Signal ground
7
RTS
Request to send
58
(GB)
-AC IN
4 5 6 7 8 9
10 11 12 13
14
15 16
MON REC
ALARM
WARNING
ALARM
FULL C
C R1 R1 ALL OUT RESET
FULL
RS-232C
Computer
5
9
Signal direction
PC t HSR
HSR t PC
HSR t PC
RS-485 terminals
to the A terminal
Modular cable
(straight type)
1) For a straight type cable, connect it between the A
connectors or between the B connectors.
For a crossed type cable, connect it from the A connector
to the B connector, or from the B connector to the A
connector.
1
1
2
2
6
1
6
3
3
4
4
5
5
6
6
Straight type
Pin arrangement of the RS-485 connector (RJ-11)
Pin No.
A connector signal
1
NC
2
NC
3
A signal
4
B signal
5
NC
6
NC
A: non-inverting driver output/input
B: inverting driver output/input
For connection, attach a ferrite core (supplied with the
HSR-X209P/X216P only) as with a LAN cable (
).
54(GB)
to the A terminal
Modular cable
(crossed type)
1
1
2
2
1
6
1
6
3
3
4
4
5
5
6
6
Crossed type
B connector signal
NC
NC
B signal
A signal
NC
NC
page
1

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hsr-x209pHsr-x216p

Table des Matières