the available alarm recording area size and
displayed in parentheses on the second line from
the bottom.
Note
As long as the normal recording area has been
established on the hard disk, the recording rate for
pre-alarm recording is fixed to 15 FPS (HSR-
X216) or 12.5 FPS (HSR-X209P/X216P). If you
cancel the normal recording area (by setting the
area to 0%), the recording cycle for pre-alarm
recording can be set to 60 FPS at maximum.
5
When you use the built-in activity detection sensor
as a trigger, set the sensing points and the
sensitivity (see the next paragraph).
6
When the settings on the ALARM REC MODE
SET display are completed, press the EXIT/OSD
button to exit the menu.
Specifying the duration for each camera
individually
Specify the duration for each camera operation
individually when you have set DURATION on the
ALARM REC MODE SET display to INDIV.
1
Move the cursor to ALARM DURATION SET on
the ALARM OPERATION SET display, then turn
the Shuttle dial clockwise.
The ALARM DURATION SET display appears.
<ALARM DURATION SET>
IN
IN
IN
01:5S
02:5S
03:5S
05:5S
06:5S
07:5S
09:5S
10:5S
11:5S
13:5S
14:5S
15:5S
(You can set only 01 to 09 with the HSR-X209P.)
2
Select the duration value for each camera input (5
sec. to 15 min. or CC) using the Jog dial, then
resister the setting by turning the Shuttle dial
clockwise.
IN
04:5S
08:5S
12:5S
16:5S
Setting the Activity Detection
Sensor
When you use the built-in activity detection sensor, it
is necessary to set the sensing points, the TIME
PERIOD during which the sensor activates, sensitivity,
and operation mode for each camera.
On the ALARM OPERATION SETTING screen,
move the cursor to ACTIVITY SENSOR, then turn the
Shuttle dial clockwise to change to the Activity
Detection Sensor Set display.
The sensor marks are displayed on a 10×16 grid on the
monitor, and the top left mark flashes.
- - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - -
01 T-1 LEVEL:10
MODE B TO A
1
Select a camera.
Press the INPUT SELECTOR button
corresponding to the camera whose activity
detection sensor is to be activated.
The number of the camera selected will be
displayed in the lower-left corner of the setting
screen.
2
Set the sensor to ON.
Turn the Jog dial so that the mark at the point
where you wish to activate the sensor flashes, then
turn the Shuttle dial clockwise to select A or B (see
step 5).
If you wish the sensor to activate when the
luminance of the whole screen becomes
homogeneous, you do not need to set to either A
or B.