Make sure the stove is not overheated - it can
cause irreparable damage to the product. Such
damage is not covered by the warranty.
Source: "Håndbok, effektiv og miljøvennlig vedfyring" by Edvard
Karlsvik SINTEF Energy Research AS and Heikki Oravainen, VTT.
For your own safety, comply with the assembly instructions.
All safety distances are minimum distances. Installation of the
fireplace must comply with the current rules and regulations
of the country where the product is installed. Nordpeis AS is
not responsible for wrongly assembled fireplaces.
Subject to errors and changes.
For the latest updated version go to www.nordpeis.com
4. Technical information:
- Salzburg M, Salzburg M High (+1)
Minimum distances to
combustible materials
(with heat shield)
CO-content of flue gas @
13%O
2
Flue gas temperature
Thermal output
Thermal storage
capacity
High
Energy efficiency
Opening of the air vent
control (%)
Nominal heat output
during discharge period
(100%-25%)
Length of wood logs
Weight Low / High base
Weight High (+1)
Load size (kg)
Max nr. loads
Loading interval
Nr. burning cycles per 24
hours
Warning!
Back
50 mm (*)
150 mm
100 mm (+1)
Side
100mm (*)
150 mm
100 mm (+1)
Ceiling
500 mm
0,1 % / 32 mg/Nm3
0,09 % / 37 mg/Nm3 (+1)
157 °C
133 °C (+1)
39,4 kWh
40,2 kWh (+1)
100% after 4,9 hrs
50% after 14,1 hrs
25% after 21,7 hrs
100% after 5,7 hrs
50% after 13 hrs
25% after 20,5 hrs
84,0%
85,2% (+1)
+/- 33 %
2,35 kW
2,7 kW (+1)
300 mm
ca. 610 kg / 629 kg
ca. 717 kg
2 kg
5
1 / hour
1

5. Before Installing a new fireplace

Several European countries have local
regulations for installation of fireplaces, which change
regularly. It is the responsibility of the client that these
regulations are complied with in the country/region
where the fireplace is installed.
Nordpeis AS is not responsible for incorrect installation.
Important to check
(please note that this list is not exhaustive):
• distance from firebox to combustible/flammable
materials
• insulation materials/requirements between
fireplace surround and back wall
• size of floor plates in front of fireplace if required
• flue connection between firebox and chimney
• insulation requirements if flue passes through a
flammable wall
• an access for cleaning the appliance, the flue gas
connector, the chimney flue must be provided

Chimney Draft

Compared to older models, the clean burning fireplaces
of today put significantly higher demands on the
chimney. Even the best fireplace will not work properly
if the chimney does not have the right dimensions or
is not in good working order. The draught is mainly
controlled by gas temperature, outside temperature, air
supply as well as the height and inner diameter of the
chimney. The diameter of the chimney should never
be less than that of the flue/chimney collar. At nominal
effect there should be a negative pressure of 12 to 25
Pascal.
The draft increases when:
• The chimney becomes warmer than the outside air
• The active length of the chimney over the hearth
increases
• Good air supply to the combustion
It can be difficult to obtain the right draught conditions
in case the chimney is too large relative to the fireplace,
as the chimney does not heat up well enough. In
such cases you may want to contact professional for
evaluation of possible measures. Draught that is too
strong can be controlled with a damper. If necessary,
contact a chimney sweeper. The product is type
tested and should be connected to a chimney that is
dimensioned for the smoke gas temperature indicated
in the CE declaration. When necessary, contact a
professional in advance
Attention! It is recommended to use a qualified
professional when installing a new fireplace.

Air supply (=mm AIR)

A set for fresh air supply is available as an accessory.
This will ensure that the air supply to the combustion
chamber is less affected by ventilation systems, kitchen
fans and other factors which can create a down-draught