Before Installing A New Stove; Chimney Draught; Air Supply; Technical Information - Nordpeis ME Série Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 36

1. Before installing a new stove

All our products are tested according to the latest
European requirements and also to the Norwegian
standard NS 3058 and NS 3059, which include particle
tests. However, several European countries have local
regulations for installation of fireplaces, which change
regularly. It is the responsibility of the client that these
regulations are complied with in the country/region
where the fireplace is installed. Nordpeis AS is not
responsible for incorrect installation.
Important to check:
distance from firebox to combustible/flammable
materials
insulation materials/requirements between
fireplace surround and back wall
size of floor plates in front of fireplace if required
flue connection between firebox and chimney
insulation requirements if flue passes through a
flammable wall

Chimney draught

Compared with older models, the clean burning stoves
of today put significantly higher demands on the
chimney. Even the best stove will not work properly
if the chimney does not have the right dimensions or
is not in good working order. The draught is mainly
controlled by gas temperature, outside temperature,
air supply as well as the height and inner diameter of
the chimney. Recommended effective chimney height
is minimum 4 meters with a diameter of 150 – 200mm.
The diameter of the chimney should never be less than
that of the flue/chimney collar.
nominal heat output, see technical table
The draught increases when:
The chimney becomes warmer than the outside air
The active length of the chimney over the hearth
increases
There is good air supply to the combustion
It can be difficult to obtain the right draught conditions
in case the chimney is too large relative to the stove,
as the chimney does not heat up well
cases you should contact professional for evaluation
of possible measures. Draught that is too strong can
be controlled with a damper. If necessary, contact a
chimney sweeper.

Air supply

A set for fresh air supply is available as accessory.
This will ensure that the air supply to the combustion
chamber is less affected by ventilation systems,
kitchen fans and other factors which can create a
down-draught in the room. In all new construction, we
strongly recommend that it is designed and prepared
for direct supply of outside air. In older houses, the use
of fresh air supply set is also
air supply can cause down-draught and thereby low
combustion efficiency and the problems that this entails:
soot stains on the glass, inefficient use of the wood and
16
For draft requirements at
enough. In such
recommended.
Insufficient
a soot deposits in the chimney.
Warning! Keep the air intakes, supplying
combustion air, free from blockage.
If the requirements for ventilation are
NOT complied with, the product can overheat.
This can cause a fire.
Warrning! Extractor fans when operating
in the same room or space as the appliance
may cause problem.
For your own safety, comply with the assembly instructions.
All safety distances are minimum distances. Installation of the
stove must comply with the current rules and regulations of
the country where the product is installed. Nordpeis AS is not
responsible for wrongly assembled stoves.
The illustrations indicate the approximate centre height of the
recess for the flue. Consider possible inclination of the flue
prior to perforating the chimney. Distortions in floors and walls
may also influence the height. Place the stove for accurate
height and positioning of the flue/chimney connection.
Subject to errors and changes.
For the latest updated version go to www.nordpeis.com.

2. Technical information

The stoves from Nordpeis all have secondary
combustion and are clean burning. The combustion
takes place in two phases: first the wood burns and
then the gases from the fumes are lit by the hot air.
This ensures that these new stoves have minimal
emissions of soot particles and un-burnt gases (such
as CO) and are thus better for the environment. Clean
burning stoves require a small amount of wood in order
to obtain a good heat output. Use exclusively clean and
dry wood. We recommend seasoned hardwood with a
maximum moisture content of 20%.
Material
Weight (kg)
with sideglass / w/o sideglass
Basic
Ceiling (the weight of the chim-
ney connection not included)
Bench
Glass
Steel
Wall with firewall
Wall without firewall
Draught system
Combustion system
Operating range, Clean burn
(kW)
GB
Steel
64 / 68
89 / 93
83 / 87
149 / 153
96 / 100
117 / 121
89 / 93
74 / 78
Air vent control
Secondary combustion
(clean burning)
3-6

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sn-me000-024Sn-me000-014

Table des Matières