18
15 Technical Data
15.1 ETS 3200 WITH INTEGRAL SENSOR PROBE
Input data
measuring range
Pressure resistance
Hydraulic connection
Tightening torque
Parts in contact with fluid
Output data
Output signals
Accuracy (display, analogue output)
Temperature drift (enviroment)
Analogue output
Switching outputs
Design
Switching current
Switching cycles
Rise time to DIN EN 60751
Parameterisation
Ambient conditions
Ambient temperature range
Storage temperature range
Fluid temperature range (for probe)
-mark
Vibration resistance to
DIN EN 60068-2-6 (0 .. 500 Hz)
Shock resistance to
DIN EN 60068-2-29 (11 ms)
Protection class to IEC 60529
Edition: 2015-04-14
-25 .. 100 °C (-13 .. 212 °F)
600 bar (probe length 18mm)
1)
50 bar
(probe length 100mm)
1)
50 bar
(probe length 250mm)
1)
50 bar
(probe length 350mm)
G1/2 A ISO 1179-2 (DIN 3852)
45 Nm
Mechanical connection: Stainless steel
Seal: FPM
Output 1: PNP transistor output
Output 2: can be configured as PNP transistor
switching output or as analogue output
≤ ± 1.0 °C (≤ ± 2.0 °F)
≤±0.015 % FS / °C (zero point and range)
selectable:
0 .. 10 V; ohmic resistance: min. 1 kΩ
4 .. 20mA; ohmic resistance ≤ 500 Ω
is equivalent to -25 .. +100°C
PNP transistor output
Programmable as N/O or N/C
SP1: max. 0.1 A
SP2: max. 0.25 A
> 100 million
Probe length 18 mm:
Probe length 100; 250; 350 mm: t
Via IO-Link interface, see chap. 7
or push buttons on the ETS 3200
-25 .. + 80 °C (-13 .. +176 °F)
-40 .. + 80 °C (-40 .. 176 °F)
1)
-40 .. +100 °C (-40 .. 212 °F) /
-25 .. +100 °C (-13 .. 212 °F)
EN 61000-6-1 / -2 / -3 / -4
≤ 10 g
≤ 50 g
IP 67
HYDAC ELECTRONIC GMBH
ETS 3000 IO-Link
t
: 3 s;
50
t
: 9s
90
: 8 s;
50
t
: 15s
90
Part No.: 669904