ETS 3000 IO-Link
Other data
Supply voltage
Current consumption
Residual ripple of supply voltage
Display
Weight (complete unit including probe)
Note:
Reverse polarity protection of the supply voltage, overvoltage, override and and short circuit protection
are provided.
FS (Full Scale) = relative to complete measuring range
1)
-25 °C with FPM seal, -40 °C on request
IO-Link-specific data:
Features
Block Parameters
Data Storage
Profile Characteristic
Supported Access Locks
Communication
IO-Link Revision
Transmission Rate, Baud Rate
Minimum Cycle Time
Process data width
SIO Mode Supported
M-Sequence Capability
* Connection with unscreened standard sensor line possible
up to a max. line length of 20 m.
Download the IO Device Description (IODD) from:
→Products→Sensors→Product Search
http://www.hydac.com/uk-en/products/sensors/show/Material/index.html
Entering the part number (9xxxxx) the corresponding ZIP file appears
Edition: 2015-04-14
9 .. 35 V DC without analogue output
18 .. 35 V DC with analogue output
≤ 0.535 A with 2 active switch outputs
≤ 35 mA with inactive switching outputs
≤ 55 mA with inactive switching output
≤ 5 %
4-digit, LED, 7-segment, red
Height of digits 7 mm
approx. 135 g (probe length: 18 mm)
approx. 150 g (probe length: 100 mm)
approx. 185 g (probe length: 250 mm)
approx. 210 g (probe length: 350 mm)
Yes
Yes
0x0001 (Device Profile: Smart Sensor),
0x8000 (Function Class: Device Identification),
0x8001 (Function Class: Binary Data Channel),
0x8002 (Function Class: Process Data Variables)
Parameters
Data Storage
Local Parameterisation
Local User Interface
V1.1 / support V1.0
38.4 kBaud * (COM2)
20 ms
16 Bit
Yes
PREOPERATE = TYPE_0
OPERATE = TYPE_2_2
ISDU supported
HYDAC ELECTRONIC GMBH
and analogue output
19
Part No.: 669904