Interruption feeding alarm (HACCP alarm).
Remedy:
-please check the device-feeding connection
HP
-please check the parameter A10 value.
Main consequences:
-the device will memorize the alarm
Interruption feeding alarm (HACCP alarm).
Remedy:
-please check the device-feeding connection
PF
-please check the parameter A10 value.
Main consequences:
-the device will memorize the alarm
Condenser overheated alarm.
Remedy:
-please check the condenser temperature
COH
-please check the parameter C6 value
Main consequences:
-the condenser fan will be activated
Compressor blocked alarm.
Remedy:
-please check the condenser temperature
-please check the parameter C7 value
CSd
-please disconnect the device feeding and clean the condenser
Main consequences:
-if the error occurs during the state "stand-by", it won't be possible to select
or start any cycle
-if the error occurs during the fonctionning cycle, the cycle will be stopped.
Download configuration parameters alarm not completed correctly.
Remedy:
-please press and release a key to restore the normal visualization
ESt
-please make the configuration parameters download again
Main consequences:
-the device will work normally
Download configuration parameters alarm not completed correctly.
Remedy:
-please press and release a key to restore the normal visualization
CEr
-please make the configuration parameters download again
Main consequences:
-the device will work normally
Configuration parameters upload alarm not completed
Remedy:
-please restore the factory setting
Erd
-please make the configuration parameter upload again.
Main consequences:
-the digital exit will be switched off.